{"schema_version":1,"layer":"water","reviewed_on":"2026-10-27","coverage_note":"Selected state reporting laws and proposals, annual operator disclosures and construction dewatering permits. Withdrawal, consumption, discharge, supply allocations and forecasts are different measures. Coverage is incomplete.","items":[{"id":"water-fl-data-center-permitting-2026","kind":"water_disclosure","subject":"Florida water permit conditions for large scale data centers","state_codes":["fl"],"scope":"Statutory water allocation and application disclosure conditions. Immediate definitions and later permit requirements are separate, and neither establishes an issued project permit, actual water use or an annual operating report.","fields":{"status":{"value":"enacted","source_ids":["fl-chapter2026-65"],"scope":"Enacted water permitting requirements, not an issued permit or actual water quantity.","locator":"Chapter sections 4 through 6 and section 8"},"approved_on":{"value":"2026-05-07","source_ids":["fl-chapter2026-65","fl-sb484-history-20261023"],"scope":"Governor approval and chapter document filing day; distinct from May 8 chapter assignment.","locator":"Chapter PDF page 7 footer and Senate bill history"},"definition_effective_on":{"value":"2026-05-07","source_ids":["fl-chapter2026-65"],"scope":"Section 4 definitions take effect upon becoming law. The operative water permit and modification provisions have the general July 1 date.","locator":"Chapter section 4 and section 8, PDF pages 5 and 7"},"permit_requirements_effective_on":{"value":"2026-07-01","source_ids":["fl-chapter2026-65"],"scope":"General effective date for sections 5 and 6, distinct from immediate definitions.","locator":"Chapter section 8, PDF page 7"},"covered_data_centers":{"value":"The large scale data center definition uses one location with a data center and at least 50 MW anticipated monthly peak load over a fifteen minute interval, including same site colocation.","source_ids":["fl-chapter2026-65"],"scope":"Separate sites are not aggregated. This power based definition is distinct from the water allocation threshold for additional application content.","locator":"Chapter section 4, PDF page 5"},"permit_criteria":{"value":"Water allocation cannot be permitted if the proposed use harms area water resources or is prohibited by applicable local zoning and comprehensive plans. Applicants must establish reasonable and beneficial use, no interference with existing legal water uses and consistency with the public interest.","source_ids":["fl-chapter2026-65"],"scope":"Conditions operate with the other applicable permit provisions. These standards do not establish a particular project approval or quantity.","locator":"Chapter section 5, subsection 2, PDF page 6"},"conditional_reclaimed_water":{"value":"Reclaimed water must replace all or part of proposed surface water or groundwater use when all stated conditions hold: a suitable permitted supply, sufficient supply lines at the property boundary, applicant access, environmental and economic and technical feasibility, and compatibility with the discharge permit.","source_ids":["fl-chapter2026-65"],"scope":"A conditional requirement with all five tests, not a universal reclaimed only rule or proof any project has such a supply or uses reclaimed water.","locator":"Chapter section 5, subsection 3, PDF page 6"},"additional_application_content":{"value":"Requests for an allocation averaging at least 100,000 gallons per day must include all water sources, amounts and losses for cooling, industrial and treatment processes, employee needs and irrigation, plus a conservation plan.","source_ids":["fl-chapter2026-65"],"scope":"An inclusive average daily allocation request threshold, not a maximum day limit, actual withdrawal, consumed amount or annual disclosure from operating facilities.","locator":"Chapter section 5, subsection 4a, PDF pages 6 and 7"},"conservation_plan":{"value":"The plan must at least address cooling water recycling before discharge or disposal, leak detection and repair, efficient fixtures and employee conservation awareness.","source_ids":["fl-chapter2026-65"],"scope":"Required plan content is not actual implementation or measured savings. It is not a requirement of zero water consumption.","locator":"Chapter section 5, subsection 4a2, PDF page 7"},"hearing_requirement":{"value":"A large scale data center water permit application cannot be approved without a hearing.","source_ids":["fl-chapter2026-65"],"scope":"The separate hearing provision is not limited to the 100,000 gallon threshold for extra application content. No actual hearing or permit outcome admitted.","locator":"Chapter section 5, subsection 4b, PDF page 7"},"permit_modifications":{"value":"A modification proposed by a large scale data center is treated like an initial application under section 373.229.","source_ids":["fl-chapter2026-65"],"scope":"The law separately covers other modifications involving at least 100,000 gallons per day. It does not exempt a smaller large scale data center modification merely because it is below that quantity.","locator":"Chapter section 6, PDF page 7"},"reported_withdrawal":{"value":null,"source_ids":["fl-chapter2026-65"],"scope":"No actual water withdrawal amount admitted from statutory criteria.","locator":"Water law review boundary","unknown_reason":"No actual water withdrawal amount admitted from statutory criteria."},"reported_consumption":{"value":null,"source_ids":["fl-chapter2026-65"],"scope":"No actual consumed amount admitted.","locator":"Water law review boundary","unknown_reason":"No actual consumed amount admitted."},"issued_project_permits":{"value":null,"source_ids":["fl-chapter2026-65"],"scope":"No individual water allocation permit reviewed.","locator":"Water law review boundary","unknown_reason":"No individual water allocation permit reviewed."},"public_annual_reports":{"value":null,"source_ids":["fl-chapter2026-65"],"scope":"These reviewed permitting provisions do not establish an actual public annual facility volume dataset. No statewide absence of other reporting requirements is inferred.","locator":"Water law review boundary","unknown_reason":"These reviewed permitting provisions do not establish an actual public annual facility volume dataset. No statewide absence of other reporting requirements is inferred."}}},{"id":"water-thermoelectric-fl-2015","kind":"water_context","subject":"Florida historical thermoelectric water context","state_codes":["fl"],"scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","fields":{"historical_thermo_withdrawal":{"value":9860.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Florida row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"historical_thermo_total_use":{"value":9900.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Florida row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"historical_thermo_consumptive_use":{"value":194.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Florida row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"status":{"value":"historical","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"report_period":{"value":"2015","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"historical_thermo_boundary":{"value":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"once_through_withdrawal":{"value":9780.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"once_through_total_water_use":{"value":9790.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"once_through_consumptive_use":{"value":127.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"recirculating_withdrawal":{"value":78.9,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"recirculating_total_water_use":{"value":111.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"recirculating_consumptive_use":{"value":67.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Florida row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"cooling_category_boundary":{"value":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Tables13A and13B headers and notes","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation."},"historical_thermo_fresh_withdrawal":{"value":434.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_freshwater_withdrawal"},"historical_thermo_saline_withdrawal":{"value":9420.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_saline_withdrawal"},"historical_thermo_fresh_consumptive_use":{"value":71.6,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_freshwater_consumption"},"historical_thermo_saline_consumptive_use":{"value":122.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_saline_consumption"},"historical_water_quality_boundary":{"value":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 headers and notes","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution."},"historical_thermo_ground_fresh_withdrawal":{"value":27.8,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_groundwater_fresh_withdrawal"},"historical_thermo_ground_saline_withdrawal":{"value":28.5,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_groundwater_saline_withdrawal"},"historical_thermo_surface_fresh_withdrawal":{"value":406.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_surfacewater_fresh_withdrawal"},"historical_thermo_surface_saline_withdrawal":{"value":9400.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_surfacewater_saline_withdrawal"},"historical_water_origin_boundary":{"value":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 groundwater and surface water headers and notes","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution."},"historical_thermo_reclaimed_water":{"value":34.5,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","unit":"million gallons per day","measurement_role":"historical_estimated_reclaimed_wastewater"},"historical_thermo_public_supply_deliveries":{"value":8.88,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","unit":"million gallons per day","measurement_role":"historical_estimated_public_supply_delivery"},"historical_water_delivery_boundary":{"value":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 reclaimed wastewater/public supply headers and dash definition","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance."},"historical_thermo_net_generation":{"value":231000.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Florida row","scope":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.","unit":"GWh","measurement_role":"historical_net_thermoelectric_generation"},"historical_generation_boundary":{"value":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 net power generated header, gigawatt hours","scope":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained."}}},{"id":"water-thermoelectric-model-2020-fl","kind":"water_context","subject":"Florida historical2020 modeled thermoelectric water context","state_codes":["fl"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","fields":{"status":{"value":"historical","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Annual output YEAR2020 and model provenance"},"thermo2020_period":{"value":"2020","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Annual CSV YEAR column"},"thermo2020_basis":{"value":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Published annual CSV/attribute definitions/catalog model limitations"},"thermo2020_model_rows":{"value":56,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_model_plant_year_rows"},"thermo2020_consumption_modeled_rows":{"value":47,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_modeled_consumption_rows"},"thermo2020_saline_consumption_unmodeled_rows":{"value":9,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_saline_consumption_unmodeled_rows"},"thermo2020_withdrawal_sum":{"value":6065.749245330535,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_model_withdrawal"},"thermo2020_withdrawal_lower_sum":{"value":2617.690440857001,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_withdrawal_lower_plausibility_limits"},"thermo2020_withdrawal_upper_sum":{"value":43803.03799631594,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_withdrawal_upper_plausibility_limits"},"thermo2020_consumption_available_sum":{"value":174.7093773650881,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_available_model_consumption"},"thermo2020_consumption_lower_available_sum":{"value":138.40437030886181,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_consumption_lower_plausibility_limits"},"thermo2020_consumption_upper_available_sum":{"value":218.71661249363044,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_consumption_upper_plausibility_limits"},"thermo2020_cooling_basis":{"value":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Annual YEAR2020 CSV coolingType and metadata coolingType domain definitions"},"thermo2020_cooling_tower_rows":{"value":36,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of FL YEAR2020 rows with exact coolingType=Recirculating Tower","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_tower_withdrawal":{"value":101.16953001578284,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Recirculating Tower","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_once_fresh_rows":{"value":1,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of FL YEAR2020 rows with exact coolingType=Once-through fresh","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_once_fresh_withdrawal":{"value":11.5014704547409,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Once-through fresh","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_complex_rows":{"value":5,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of FL YEAR2020 rows with exact coolingType=Complex","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_complex_withdrawal":{"value":1973.655531797679,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Complex","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_once_saline_rows":{"value":9,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of FL YEAR2020 rows with exact coolingType=Once-through saline","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_once_saline_withdrawal":{"value":3923.364525580456,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Once-through saline","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_pond_rows":{"value":5,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of FL YEAR2020 rows with exact coolingType=Recirculating pond","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_pond_withdrawal":{"value":56.05818748187619,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Recirculating pond","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"}}}],"sources":{"fl-chapter2026-65":{"url":"https://laws.flrules.org/2026/65","title":"Florida Chapter 2026-65, final enacted data center law","publisher":"Florida Department of State, Laws of Florida","published_on":null,"date_note":"The document records May 7 approval and filing. Its original online publication day is not independently stated.","checked_at":"2026-10-23T19:09:57.104826+00:00","sha256":"0dc90eb9be05a9e6a9f50ae961bce3d12ec5978c9b5171c7c7c1b16811534411","scope":"Seven page enacted law. Electric tariff filing requirements and water permit standards are separate from individual approvals, actual load and actual water use. General July 1 effectiveness has express exceptions.","tier":"A","establishes_status":["enacted"]},"fl-sb484-history-20261023":{"url":"https://www.flsenate.gov/Session/Bill/2026/484","title":"Florida Senate SB 484 bill history, October 23 capture","publisher":"Florida Senate","published_on":null,"date_note":"Dynamic bill history has no single original publication day. May 7 approval and May 8 chapter assignment are distinct entries.","checked_at":"2026-10-23T19:09:57.642980+00:00","sha256":"58bcebd34f1d42ae4eca6d66928933791fdccba3ad00e2b23bf7a6c08fee9029","scope":"Corroborates May 7 Governor approval, May 8 chapter assignment and general July 1 effectiveness except as otherwise provided. A legislative milestone does not establish an individual tariff or water permit.","tier":"A","establishes_status":["enacted"]},"usgs-thermoelectric-2015-circular1441":{"url":"https://pubs.usgs.gov/circ/1441/circ1441.pdf","title":"USGS Circular1441 Tables12,13A,13B historical thermoelectric water2015","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Report explicitly2018, exact publication day not established from reviewed pages. Estimates represent2015, not capture2026.","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","checked_at":"2026-10-26T16:26:24.100526+00:00","sha256":"ef0e2caa3bd7769fde0de383f6668ba2559d8b716a38bfec6bed027729061f88","tier":"A","establishes_status":["historical"],"reviewed_cooling_pages":[{"physical_page":56,"printed_page":48,"actually_viewed":true,"image_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261024/usgs-water2015-cooling-56.png","image_sha256":"2679f353db6b2f6ecf3949271cdc27ee7a233e3a481ec48e634b455476967992","whole_report_read":false},{"physical_page":57,"printed_page":49,"actually_viewed":true,"image_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261024/usgs-water2015-cooling-57.png","image_sha256":"91b53a88319f53e4aaf723464e70bccb80da89f237483345d7433dfd3de7a635","whole_report_read":false}]},"usgs-thermo2020-annual-member":{"url":"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443","title":"Published annual thermoelectric water model output2008-2020;2020 selection","publisher":"U.S. Geological Survey","published_on":"2023-10-31","date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:08:53.974305+00:00","sha256":"f19e1026cf5379a2d47a27412834365742f8b6b59aa9aeb8692543dcf18c7664","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-published-annual.csv","tier":"A","establishes_status":["historical"],"member":"4_model_results/published_annual_thermoelectric_water_use_estimates_2008-2020.csv","member_crc32":4031126398,"container_sha256":"2c365899da6a8016aa6da39265eeea0e7b4555dcd3f8b8fcf3c05b181409d54c","container_bytes":681440737,"container_raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-galanter2023-published-archive.zip"},"usgs-thermo-reanalysis-attribute-definitions":{"url":"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02","title":"Annual thermoelectric model attribute definitions","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:10:39.568488+00:00","sha256":"da1a426d2920c63a91a66ac5c45cc21541d8f0fb807275491570c49f9356dda3","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-attributes-20261027.bin","tier":"A","establishes_status":["historical"]},"usgs-thermo-reanalysis-catalog":{"url":"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json","title":"Thermoelectric reanalysis2008-2020 catalog and limitations","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:05:54.160633+00:00","sha256":"782d5e88048b3a7d076539539a78a4beb382d5891ae5fa84f77d87fcdd5d5cc1","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-catalog-json-20261027.bin","tier":"A","establishes_status":["historical"]}},"details":[{"id":"water-fl-data-center-permitting-2026","html":"<article><h3>Florida water permit conditions for large scale data centers</h3><p class=\"layer-scope\">Statutory water allocation and application disclosure conditions. Immediate definitions and later permit requirements are separate, and neither establishes an issued project permit, actual water use or an annual operating report.</p><dl class=\"layer-fields\"><dt>Status</dt><dd>enacted<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Enacted water permitting requirements, not an issued permit or actual water quantity. Locator: Chapter sections 4 through 6 and section 8.</p></dd><dt>Approved on</dt><dd>May 7, 2026<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.flsenate.gov/Session/Bill/2026/484\">Florida Senate</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Governor approval and chapter document filing day; distinct from May 8 chapter assignment. Locator: Chapter PDF page 7 footer and Senate bill history.</p></dd><dt>Definition effective on</dt><dd>May 7, 2026<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Section 4 definitions take effect upon becoming law. The operative water permit and modification provisions have the general July 1 date. Locator: Chapter section 4 and section 8, PDF pages 5 and 7.</p></dd><dt>Permit requirements effective on</dt><dd>July 1, 2026<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">General effective date for sections 5 and 6, distinct from immediate definitions. Locator: Chapter section 8, PDF page 7.</p></dd><dt>Covered data centers</dt><dd>The large scale data center definition uses one location with a data center and at least 50 MW anticipated monthly peak load over a fifteen minute interval, including same site colocation.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Separate sites are not aggregated. This power based definition is distinct from the water allocation threshold for additional application content. Locator: Chapter section 4, PDF page 5.</p></dd><dt>Permit criteria</dt><dd>Water allocation cannot be permitted if the proposed use harms area water resources or is prohibited by applicable local zoning and comprehensive plans. Applicants must establish reasonable and beneficial use, no interference with existing legal water uses and consistency with the public interest.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Conditions operate with the other applicable permit provisions. These standards do not establish a particular project approval or quantity. Locator: Chapter section 5, subsection 2, PDF page 6.</p></dd><dt>Conditional reclaimed water</dt><dd>Reclaimed water must replace all or part of proposed surface water or groundwater use when all stated conditions hold: a suitable permitted supply, sufficient supply lines at the property boundary, applicant access, environmental and economic and technical feasibility, and compatibility with the discharge permit.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">A conditional requirement with all five tests, not a universal reclaimed only rule or proof any project has such a supply or uses reclaimed water. Locator: Chapter section 5, subsection 3, PDF page 6.</p></dd><dt>Additional application content</dt><dd>Requests for an allocation averaging at least 100,000 gallons per day must include all water sources, amounts and losses for cooling, industrial and treatment processes, employee needs and irrigation, plus a conservation plan.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">An inclusive average daily allocation request threshold, not a maximum day limit, actual withdrawal, consumed amount or annual disclosure from operating facilities. Locator: Chapter section 5, subsection 4a, PDF pages 6 and 7.</p></dd><dt>Conservation plan</dt><dd>The plan must at least address cooling water recycling before discharge or disposal, leak detection and repair, efficient fixtures and employee conservation awareness.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">Required plan content is not actual implementation or measured savings. It is not a requirement of zero water consumption. Locator: Chapter section 5, subsection 4a2, PDF page 7.</p></dd><dt>Hearing requirement</dt><dd>A large scale data center water permit application cannot be approved without a hearing.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">The separate hearing provision is not limited to the 100,000 gallon threshold for extra application content. No actual hearing or permit outcome admitted. Locator: Chapter section 5, subsection 4b, PDF page 7.</p></dd><dt>Permit modifications</dt><dd>A modification proposed by a large scale data center is treated like an initial application under section 373.229.<span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">The law separately covers other modifications involving at least 100,000 gallons per day. It does not exempt a smaller large scale data center modification merely because it is below that quantity. Locator: Chapter section 6, PDF page 7.</p></dd><dt>Reported withdrawal</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">No actual water withdrawal amount admitted from statutory criteria. Locator: Water law review boundary.</p></dd><dt>Reported consumption</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">No actual consumed amount admitted. Locator: Water law review boundary.</p></dd><dt>Issued project permits</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">No individual water allocation permit reviewed. Locator: Water law review boundary.</p></dd><dt>Public annual reports</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://laws.flrules.org/2026/65\">Florida Department of State, Laws of Florida</a>. Source: Publication date not stated. Checked: October 23, 2026.</span> <p class=\"layer-scope\">These reviewed permitting provisions do not establish an actual public annual facility volume dataset. No statewide absence of other reporting requirements is inferred. Locator: Water law review boundary.</p></dd></dl></article>"},{"id":"water-thermoelectric-fl-2015","html":"<article><h3>Florida historical thermoelectric water context</h3><p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.</p><dl class=\"layer-fields\"><dt>Historical thermo withdrawal</dt><dd>9860.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Florida row.</p></dd><dt>Historical thermo total use</dt><dd>9900.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Florida row.</p></dd><dt>Historical thermo consumptive use</dt><dd>194.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Florida row.</p></dd><dt>Status</dt><dd>historical<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Report period</dt><dd>2015<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Historical thermo boundary</dt><dd>Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Once through withdrawal</dt><dd>9780.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Florida row.</p></dd><dt>Once through total water use</dt><dd>9790.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Florida row.</p></dd><dt>Once through consumptive use</dt><dd>127.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Florida row.</p></dd><dt>Recirculating withdrawal</dt><dd>78.90 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Florida row.</p></dd><dt>Recirculating total water use</dt><dd>111.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Florida row.</p></dd><dt>Recirculating consumptive use</dt><dd>67.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Florida row.</p></dd><dt>Cooling category boundary</dt><dd>Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Tables13A and13B headers and notes.</p></dd><dt>Historical thermo fresh withdrawal</dt><dd>434.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo saline withdrawal</dt><dd>9420.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo fresh consumptive use</dt><dd>71.60 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo saline consumptive use</dt><dd>122.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical water quality boundary</dt><dd>Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12 headers and notes.</p></dd><dt>Historical thermo ground fresh withdrawal</dt><dd>27.80 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo ground saline withdrawal</dt><dd>28.50 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo surface fresh withdrawal</dt><dd>406.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo surface saline withdrawal</dt><dd>9400.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical water origin boundary</dt><dd>Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12 groundwater and surface water headers and notes.</p></dd><dt>Historical thermo reclaimed water</dt><dd>34.50 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical thermo public supply deliveries</dt><dd>8.88 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical water delivery boundary</dt><dd>Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12 reclaimed wastewater/public supply headers and dash definition.</p></dd><dt>Historical thermo net generation</dt><dd>231000.00 GWh<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained. Locator: Table12,physical51,printed43; Florida row.</p></dd><dt>Historical generation boundary</dt><dd>Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained. Locator: Table12 net power generated header, gigawatt hours.</p></dd></dl></article>"},{"id":"water-thermoelectric-model-2020-fl","html":"<article><h3>Florida historical2020 modeled thermoelectric water context</h3><p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.</p><dl class=\"layer-fields\"><dt>Status</dt><dd>historical<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Annual output YEAR2020 and model provenance.</p></dd><dt>Thermo2020 period</dt><dd>2020<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Annual CSV YEAR column.</p></dd><dt>Thermo2020 basis</dt><dd>USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Published annual CSV/attribute definitions/catalog model limitations.</p></dd><dt>Thermo2020 model rows</dt><dd>56 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption modeled rows</dt><dd>47 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 saline consumption unmodeled rows</dt><dd>9 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal sum</dt><dd>6065.75 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal lower sum</dt><dd>2617.69 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal upper sum</dt><dd>43803.04 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption available sum</dt><dd>174.71 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption lower available sum</dt><dd>138.40 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption upper available sum</dt><dd>218.72 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 FL rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 cooling basis</dt><dd>Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Annual YEAR2020 CSV coolingType and metadata coolingType domain definitions.</p></dd><dt>Thermo2020 cooling tower rows</dt><dd>36 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of FL YEAR2020 rows with exact coolingType=Recirculating Tower.</p></dd><dt>Thermo2020 cooling tower withdrawal</dt><dd>101.17 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Recirculating Tower.</p></dd><dt>Thermo2020 cooling once fresh rows</dt><dd>1 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of FL YEAR2020 rows with exact coolingType=Once-through fresh.</p></dd><dt>Thermo2020 cooling once fresh withdrawal</dt><dd>11.50 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Once-through fresh.</p></dd><dt>Thermo2020 cooling complex rows</dt><dd>5 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of FL YEAR2020 rows with exact coolingType=Complex.</p></dd><dt>Thermo2020 cooling complex withdrawal</dt><dd>1973.66 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Complex.</p></dd><dt>Thermo2020 cooling once saline rows</dt><dd>9 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of FL YEAR2020 rows with exact coolingType=Once-through saline.</p></dd><dt>Thermo2020 cooling once saline withdrawal</dt><dd>3923.36 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Once-through saline.</p></dd><dt>Thermo2020 cooling pond rows</dt><dd>5 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of FL YEAR2020 rows with exact coolingType=Recirculating pond.</p></dd><dt>Thermo2020 cooling pond withdrawal</dt><dd>56.06 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for FL YEAR2020 exact coolingType=Recirculating pond.</p></dd></dl></article>"}]}