{"schema_version":1,"layer":"water","reviewed_on":"2026-10-27","coverage_note":"Selected state reporting laws and proposals, annual operator disclosures and construction dewatering permits. Withdrawal, consumption, discharge, supply allocations and forecasts are different measures. Coverage is incomplete.","items":[{"id":"water-mi-part327-20261025","kind":"water_reporting_context","subject":"Michigan large withdrawal authorization and averaging boundaries","state_codes":["mi"],"scope":"Capacity versus actual use, common distribution and zone qualifiers, exact seasonal threshold and registration authorization.","fields":{"status":{"value":"program","source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"mi_water_basis":{"value":"Selected large withdrawal definitions and permit routes, not actual pumping or universal approval","source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"definition_scope":{"value":"MCL32701defines large quantity withdrawal as cumulative total over100000gallons daily average in any consecutive30days supplying common distribution system.","source_ids":["mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"increase_scope":{"value":"New or increased large quantity withdrawal exceeds100000gallons daily average over consecutive30days beyond baseline; maintenance or replacement excluded from new or increased capacity definition.","source_ids":["mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"capacity_boundary":{"value":"Agency screens property combined pump capacity, not measured actual use; statutory common distribution and averaging qualifiers retained.","source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"high_capacity_gate":{"value":"Selected32723sub1aandb require permit for new or increased capacity more than2000000gallons daily to common distribution system, increased capacity measured beyond baseline.","source_ids":["mi-water-law32723-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"zone_c_gate":{"value":"More than1000000gallons daily new or increased large withdrawal to common distribution system where site specific review determines zoneC; not any unspecified low availability location.","source_ids":["mi-water-law32723-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"intrabasin_gate":{"value":"New or increased capacity causing intrabasin transfer more than100000gallons daily average over any90days requires permit under selected provision.","source_ids":["mi-water-law32723-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"seasonal_exception":{"value":"Selected32723sub13b excludes seasonal common distribution withdrawal not more than2000000gallons daily average over consecutive90days unless diversion.","source_ids":["mi-water-law32723-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"seasonal_boundary":{"value":"Statute not more than2000000includes exact2000000; agency summary less than wording differs. This is a permit exception, not complete registration exemption.","source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"other_selected_exceptions":{"value":"Selectedsub13includes community supply holding Safe Drinking Water Act permit and bottled production approved through statutory water source review.","source_ids":["mi-water-law32723-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"temporary_unknown":{"value":"Agency also describes temporary total less180million gallon route. Relationship to selectedsub13not resolved here; not treated as absent or unlawful throughout Part327.","source_ids":["mi-water-permit-guidance-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"assessment_route":{"value":"Agency says passing assessment tool permits immediate registration and registration receipt is legal withdrawal authorization; failed screen may request site specific or third party review, not automatic approval.","source_ids":["mi-water-permit-guidance-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"change_notice":{"value":"Agency requires revised assessment and notification if installation or operation differs from tool or site specific authorization.","source_ids":["mi-water-permit-guidance-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"scope_boundary":{"value":"No full Part327review, current complete registration exceptions, specific project eligibility, actual use or exact record match.","source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance."},"individual_authorization":{"value":null,"source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance.","unknown_reason":"No individual authorization, measured use, compliance or record match reviewed."},"actual_water_use":{"value":null,"source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance.","unknown_reason":"No individual authorization, measured use, compliance or record match reviewed."},"actual_compliance":{"value":null,"source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance.","unknown_reason":"No individual authorization, measured use, compliance or record match reviewed."},"atlas_record_id":{"value":null,"source_ids":["mi-water-permit-guidance-20261025","mi-water-law32723-20261025","mi-water-law32701-20261025"],"scope":"Selected statutory and agency framework; all averaging periods and unresolved summaries retained.","locator":"MCL32701aa,cc,dd;32723sub1and13; agency guidance.","unknown_reason":"No individual authorization, measured use, compliance or record match reviewed."}}},{"id":"water-thermoelectric-mi-2015","kind":"water_context","subject":"Michigan historical thermoelectric water context","state_codes":["mi"],"scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","fields":{"historical_thermo_withdrawal":{"value":7800.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Michigan row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"historical_thermo_total_use":{"value":7800.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Michigan row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"historical_thermo_consumptive_use":{"value":117.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,printed43,physical51; Michigan row","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"status":{"value":"historical","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"report_period":{"value":"2015","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"historical_thermo_boundary":{"value":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 header and notes; thermoelectric section printed42","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation."},"once_through_withdrawal":{"value":7620.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"once_through_total_water_use":{"value":7620.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"once_through_consumptive_use":{"value":70.2,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13A,physical56,printed48; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"recirculating_withdrawal":{"value":183.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_withdrawal"},"recirculating_total_water_use":{"value":183.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_total_water_use"},"recirculating_consumptive_use":{"value":46.9,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table13B,physical57,printed49; Michigan row","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","unit":"million gallons per day","measurement_role":"historical_estimated_consumption"},"cooling_category_boundary":{"value":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Tables13A and13B headers and notes","scope":"Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation."},"historical_thermo_fresh_withdrawal":{"value":7800.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_freshwater_withdrawal"},"historical_thermo_saline_withdrawal":{"value":0.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_saline_withdrawal"},"historical_thermo_fresh_consumptive_use":{"value":117.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_freshwater_consumption"},"historical_thermo_saline_consumptive_use":{"value":0.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_saline_consumption"},"historical_water_quality_boundary":{"value":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 headers and notes","scope":"Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution."},"historical_thermo_ground_fresh_withdrawal":{"value":5.61,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_groundwater_fresh_withdrawal"},"historical_thermo_ground_saline_withdrawal":{"value":0.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_groundwater_saline_withdrawal"},"historical_thermo_surface_fresh_withdrawal":{"value":7800.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_surfacewater_fresh_withdrawal"},"historical_thermo_surface_saline_withdrawal":{"value":0.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","unit":"million gallons per day","measurement_role":"historical_estimated_surfacewater_saline_withdrawal"},"historical_water_origin_boundary":{"value":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 groundwater and surface water headers and notes","scope":"Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution."},"historical_thermo_reclaimed_water":{"value":null,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","unit":"million gallons per day","measurement_role":"historical_estimated_reclaimed_wastewater","unknown_reason":"USGS Table12 reports a dash, defined as not estimated; no zero or absence inferred."},"historical_thermo_public_supply_deliveries":{"value":null,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","unit":"million gallons per day","measurement_role":"historical_estimated_public_supply_delivery","unknown_reason":"USGS Table12 reports a dash, defined as not estimated; no zero or absence inferred."},"historical_water_delivery_boundary":{"value":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 reclaimed wastewater/public supply headers and dash definition","scope":"Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance."},"historical_thermo_net_generation":{"value":102000.0,"source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12,physical51,printed43; Michigan row","scope":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.","unit":"GWh","measurement_role":"historical_net_thermoelectric_generation"},"historical_generation_boundary":{"value":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.","source_ids":["usgs-thermoelectric-2015-circular1441"],"locator":"Table12 net power generated header, gigawatt hours","scope":"Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained."}}},{"id":"water-thermoelectric-model-2020-mi","kind":"water_context","subject":"Michigan historical2020 modeled thermoelectric water context","state_codes":["mi"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","fields":{"status":{"value":"historical","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Annual output YEAR2020 and model provenance"},"thermo2020_period":{"value":"2020","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Annual CSV YEAR column"},"thermo2020_basis":{"value":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Published annual CSV/attribute definitions/catalog model limitations"},"thermo2020_model_rows":{"value":32,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_model_plant_year_rows"},"thermo2020_consumption_modeled_rows":{"value":32,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_modeled_consumption_rows"},"thermo2020_saline_consumption_unmodeled_rows":{"value":0,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"plant-year rows","measurement_role":"calculated_count_saline_consumption_unmodeled_rows"},"thermo2020_withdrawal_sum":{"value":4626.904573950208,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_model_withdrawal"},"thermo2020_withdrawal_lower_sum":{"value":2113.9084943688263,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_withdrawal_lower_plausibility_limits"},"thermo2020_withdrawal_upper_sum":{"value":34359.209863710974,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_withdrawal_upper_plausibility_limits"},"thermo2020_consumption_available_sum":{"value":79.72652270213366,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_available_model_consumption"},"thermo2020_consumption_lower_available_sum":{"value":62.396657782025066,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_consumption_lower_plausibility_limits"},"thermo2020_consumption_upper_available_sum":{"value":96.0555752901842,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","locator":"Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval","unit":"million gallons per day","measurement_role":"calculated_sum_consumption_upper_plausibility_limits"},"thermo2020_cooling_basis":{"value":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Annual YEAR2020 CSV coolingType and metadata coolingType domain definitions"},"thermo2020_cooling_tower_rows":{"value":17,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of MI YEAR2020 rows with exact coolingType=Recirculating Tower","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_tower_withdrawal":{"value":37.55867832228408,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Recirculating Tower","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_once_fresh_rows":{"value":11,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of MI YEAR2020 rows with exact coolingType=Once-through fresh","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_once_fresh_withdrawal":{"value":4426.86042418133,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Once-through fresh","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_complex_rows":{"value":3,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of MI YEAR2020 rows with exact coolingType=Complex","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_complex_withdrawal":{"value":160.56856960843223,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Complex","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_once_saline_rows":{"value":0,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of MI YEAR2020 rows with exact coolingType=Once-through saline","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_once_saline_withdrawal":{"value":0.0,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Once-through saline","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"},"thermo2020_cooling_pond_rows":{"value":1,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated count of MI YEAR2020 rows with exact coolingType=Recirculating pond","unit":"plant-year rows","measurement_role":"calculated_count_model_cooling_category_rows"},"thermo2020_cooling_pond_withdrawal":{"value":1.91690183816161,"source_ids":["usgs-thermo2020-annual-member","usgs-thermo-reanalysis-attribute-definitions","usgs-thermo-reanalysis-catalog"],"scope":"Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.","locator":"Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Recirculating pond","unit":"million gallons per day","measurement_role":"calculated_sum_model_cooling_category_withdrawal"}}}],"sources":{"mi-water-permit-guidance-20261025":{"url":"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits","checked_at":"2026-10-25T03:18:55.351110+00:00","sha256":"53d6ddaf3752ae9cee58755383506b6d0778d04fbe152a1b40ff30a10e643690","title":"Michigan Part327 permit and registration guidance","publisher":"Michigan EGLE","tier":"A","published_on":null,"date_note":"Current official statute header complete throughPA114of2026; exact online publication day unknown.","scope":"Entire substantive agency guidance reviewed; only selected definitions32701aa,cc,dd and32723subsections1and13 reviewed. Not full Part327 or complete exception inventory.","establishes_status":["program"]},"mi-water-law32723-20261025":{"url":"https://legislature.mi.gov/doc.aspx?mcl-324-32723","checked_at":"2026-10-25T03:23:56.569954+00:00","sha256":"4d4e8b54ff9fd1342353e2fe0892e70fcdd669cb86def7de62779dc55d71a188","title":"Michigan selected MCL32723permit provisions","publisher":"Michigan Legislature","tier":"A","published_on":null,"date_note":"Current official statute header complete throughPA114of2026; exact online publication day unknown.","scope":"Entire substantive agency guidance reviewed; only selected definitions32701aa,cc,dd and32723subsections1and13 reviewed. Not full Part327 or complete exception inventory.","establishes_status":["program"]},"mi-water-law32701-20261025":{"url":"https://legislature.mi.gov/doc.aspx?mcl-324-32701","checked_at":"2026-10-25T03:23:57.708001+00:00","sha256":"f04b2a6c483c07f54601235a4d9620cd00cf93e4b09dca9270de74fff158be9b","title":"Michigan selected MCL32701definitions","publisher":"Michigan Legislature","tier":"A","published_on":null,"date_note":"Current official statute header complete throughPA114of2026; exact online publication day unknown.","scope":"Entire substantive agency guidance reviewed; only selected definitions32701aa,cc,dd and32723subsections1and13 reviewed. Not full Part327 or complete exception inventory.","establishes_status":["program"]},"usgs-thermoelectric-2015-circular1441":{"url":"https://pubs.usgs.gov/circ/1441/circ1441.pdf","title":"USGS Circular1441 Tables12,13A,13B historical thermoelectric water2015","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Report explicitly2018, exact publication day not established from reviewed pages. Estimates represent2015, not capture2026.","scope":"Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.","checked_at":"2026-10-26T16:26:24.100526+00:00","sha256":"ef0e2caa3bd7769fde0de383f6668ba2559d8b716a38bfec6bed027729061f88","tier":"A","establishes_status":["historical"],"reviewed_cooling_pages":[{"physical_page":56,"printed_page":48,"actually_viewed":true,"image_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261024/usgs-water2015-cooling-56.png","image_sha256":"2679f353db6b2f6ecf3949271cdc27ee7a233e3a481ec48e634b455476967992","whole_report_read":false},{"physical_page":57,"printed_page":49,"actually_viewed":true,"image_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261024/usgs-water2015-cooling-57.png","image_sha256":"91b53a88319f53e4aaf723464e70bccb80da89f237483345d7433dfd3de7a635","whole_report_read":false}]},"usgs-thermo2020-annual-member":{"url":"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443","title":"Published annual thermoelectric water model output2008-2020;2020 selection","publisher":"U.S. Geological Survey","published_on":"2023-10-31","date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:08:53.974305+00:00","sha256":"f19e1026cf5379a2d47a27412834365742f8b6b59aa9aeb8692543dcf18c7664","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-published-annual.csv","tier":"A","establishes_status":["historical"],"member":"4_model_results/published_annual_thermoelectric_water_use_estimates_2008-2020.csv","member_crc32":4031126398,"container_sha256":"2c365899da6a8016aa6da39265eeea0e7b4555dcd3f8b8fcf3c05b181409d54c","container_bytes":681440737,"container_raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-galanter2023-published-archive.zip"},"usgs-thermo-reanalysis-attribute-definitions":{"url":"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02","title":"Annual thermoelectric model attribute definitions","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:10:39.568488+00:00","sha256":"da1a426d2920c63a91a66ac5c45cc21541d8f0fb807275491570c49f9356dda3","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-attributes-20261027.bin","tier":"A","establishes_status":["historical"]},"usgs-thermo-reanalysis-catalog":{"url":"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json","title":"Thermoelectric reanalysis2008-2020 catalog and limitations","publisher":"U.S. Geological Survey","published_on":null,"date_note":"Catalog dataset publication2023-10-31;individual metadata revision day not established.","scope":"USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.","checked_at":"2026-10-27T22:05:54.160633+00:00","sha256":"782d5e88048b3a7d076539539a78a4beb382d5891ae5fa84f77d87fcdd5d5cc1","raw_path":"/Users/shaunwilson/Documents/Data Centers Atlas/build/cache/layers-20261023/usgs-thermo-reanalysis-catalog-json-20261027.bin","tier":"A","establishes_status":["historical"]}},"details":[{"id":"water-mi-part327-20261025","html":"<article><h3>Michigan large withdrawal authorization and averaging boundaries</h3><p class=\"layer-scope\">Capacity versus actual use, common distribution and zone qualifiers, exact seasonal threshold and registration authorization.</p><dl class=\"layer-fields\"><dt>Status</dt><dd>program<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Mi water basis</dt><dd>Selected large withdrawal definitions and permit routes, not actual pumping or universal approval<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Definition scope</dt><dd>MCL32701defines large quantity withdrawal as cumulative total over100000gallons daily average in any consecutive30days supplying common distribution system.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Increase scope</dt><dd>New or increased large quantity withdrawal exceeds100000gallons daily average over consecutive30days beyond baseline; maintenance or replacement excluded from new or increased capacity definition.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Capacity boundary</dt><dd>Agency screens property combined pump capacity, not measured actual use; statutory common distribution and averaging qualifiers retained.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>High capacity gate</dt><dd>Selected32723sub1aandb require permit for new or increased capacity more than2000000gallons daily to common distribution system, increased capacity measured beyond baseline.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Zone c gate</dt><dd>More than1000000gallons daily new or increased large withdrawal to common distribution system where site specific review determines zoneC; not any unspecified low availability location.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Intrabasin gate</dt><dd>New or increased capacity causing intrabasin transfer more than100000gallons daily average over any90days requires permit under selected provision.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Seasonal exception</dt><dd>Selected32723sub13b excludes seasonal common distribution withdrawal not more than2000000gallons daily average over consecutive90days unless diversion.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Seasonal boundary</dt><dd>Statute not more than2000000includes exact2000000; agency summary less than wording differs. This is a permit exception, not complete registration exemption.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Other selected exceptions</dt><dd>Selectedsub13includes community supply holding Safe Drinking Water Act permit and bottled production approved through statutory water source review.<span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Temporary unknown</dt><dd>Agency also describes temporary total less180million gallon route. Relationship to selectedsub13not resolved here; not treated as absent or unlawful throughout Part327.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Assessment route</dt><dd>Agency says passing assessment tool permits immediate registration and registration receipt is legal withdrawal authorization; failed screen may request site specific or third party review, not automatic approval.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Change notice</dt><dd>Agency requires revised assessment and notification if installation or operation differs from tool or site specific authorization.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Scope boundary</dt><dd>No full Part327review, current complete registration exceptions, specific project eligibility, actual use or exact record match.<span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Individual authorization</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Actual water use</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Actual compliance</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd><dt>Atlas record id</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://www.michigan.gov/egle/about/organization/geologic-resources-management/groundwater/water-use/permits\">Michigan EGLE</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32723\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <span class=\"layer-source\"><a href=\"https://legislature.mi.gov/doc.aspx?mcl-324-32701\">Michigan Legislature</a>. Source: Publication date not stated. Checked: October 25, 2026.</span> <p class=\"layer-scope\">Selected statutory and agency framework; all averaging periods and unresolved summaries retained. Locator: MCL32701aa,cc,dd;32723sub1and13; agency guidance..</p></dd></dl></article>"},{"id":"water-thermoelectric-mi-2015","html":"<article><h3>Michigan historical thermoelectric water context</h3><p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.</p><dl class=\"layer-fields\"><dt>Historical thermo withdrawal</dt><dd>7800.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Michigan row.</p></dd><dt>Historical thermo total use</dt><dd>7800.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Michigan row.</p></dd><dt>Historical thermo consumptive use</dt><dd>117.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12,printed43,physical51; Michigan row.</p></dd><dt>Status</dt><dd>historical<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Report period</dt><dd>2015<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Historical thermo boundary</dt><dd>Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 state thermoelectric power estimates, including fresh and saline water. Not current2026 conditions, data center facility use, drinking water demand, permit allocation or proof of a data center effect. Withdrawal, total water use including deliveries and reclaimed wastewater, and consumptive use are distinct. Consumption may exceed withdrawal because other supplied water is included. Independent rounding is retained; no facility joins or per kWh allocation. Locator: Table12 header and notes; thermoelectric section printed42.</p></dd><dt>Once through withdrawal</dt><dd>7620.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Michigan row.</p></dd><dt>Once through total water use</dt><dd>7620.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Michigan row.</p></dd><dt>Once through consumptive use</dt><dd>70.20 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13A,physical56,printed48; Michigan row.</p></dd><dt>Recirculating withdrawal</dt><dd>183.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Michigan row.</p></dd><dt>Recirculating total water use</dt><dd>183.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Michigan row.</p></dd><dt>Recirculating consumptive use</dt><dd>46.90 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Table13B,physical57,printed49; Michigan row.</p></dd><dt>Cooling category boundary</dt><dd>Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical2015 thermoelectric power cooling categories: once through and recirculating. These are power plant cooling estimates, not data center cooling technology or current facility use. Withdrawal, total water use including supplied and reclaimed water, and consumptive use remain distinct. Published zero differs from not estimated. Independently rounded cooling totals are not forced to equal Table12 totals; no facility or per kWh allocation. Locator: Tables13A and13B headers and notes.</p></dd><dt>Historical thermo fresh withdrawal</dt><dd>7800.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo saline withdrawal</dt><dd>0.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo fresh consumptive use</dt><dd>117.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo saline consumptive use</dt><dd>0.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical water quality boundary</dt><dd>Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power water quality categories, fresh and saline. These are not potable water classifications, current data center use or municipal drinking water allocations. Withdrawal differs from consumptive use; supplied and reclaimed water contributions retain their separate definitions. Independently rounded fresh and saline values are not forced to equal the published total. No facility or per kWh attribution. Locator: Table12 headers and notes.</p></dd><dt>Historical thermo ground fresh withdrawal</dt><dd>5.61 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo ground saline withdrawal</dt><dd>0.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo surface fresh withdrawal</dt><dd>7800.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo surface saline withdrawal</dt><dd>0.00 million gallons per day<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical water origin boundary</dt><dd>Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power withdrawals by groundwater and surface water, each separated into fresh and saline. These are state power generation estimates, not current data center water demand, aquifer stress, potable supply, permits or facility allocations. Withdrawal is not consumption. Independently rounded components are not forced to equal published totals; no facility or per kWh attribution. Locator: Table12 groundwater and surface water headers and notes.</p></dd><dt>Historical thermo reclaimed water</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical thermo public supply deliveries</dt><dd><span class=\"layer-empty\">Not established</span><span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical water delivery boundary</dt><dd>Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 thermoelectric power reclaimed wastewater and freshwater public supply deliveries, in million gallons per day. These inputs differ from direct withdrawals and consumptive use. A source dash means not estimated, not zero or no use; published zeros remain zero. No current data center use, potable quality certification, local supply allocation, permit, facility or per kWh inference. Independently rounded values are not forced to balance. Locator: Table12 reclaimed wastewater/public supply headers and dash definition.</p></dd><dt>Historical thermo net generation</dt><dd>102000.00 GWh<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained. Locator: Table12,physical51,printed43; Michigan row.</p></dd><dt>Historical generation boundary</dt><dd>Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained.<span class=\"layer-source\"><a href=\"https://pubs.usgs.gov/circ/1441/circ1441.pdf\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 26, 2026.</span> <p class=\"layer-scope\">Historical 2015 net thermoelectric power generated in gigawatt hours, from the same USGS state table as water estimates. Net generation is energy, not installed capacity, peak load, gross generation, electricity sales or data center electricity use. No current-year, facility, water intensity or per kWh allocation inferred; independently rounded source values retained. Locator: Table12 net power generated header, gigawatt hours.</p></dd></dl></article>"},{"id":"water-thermoelectric-model-2020-mi","html":"<article><h3>Michigan historical2020 modeled thermoelectric water context</h3><p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.</p><dl class=\"layer-fields\"><dt>Status</dt><dd>historical<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Annual output YEAR2020 and model provenance.</p></dd><dt>Thermo2020 period</dt><dd>2020<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Annual CSV YEAR column.</p></dd><dt>Thermo2020 basis</dt><dd>USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference.<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Published annual CSV/attribute definitions/catalog model limitations.</p></dd><dt>Thermo2020 model rows</dt><dd>32 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption modeled rows</dt><dd>32 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 saline consumption unmodeled rows</dt><dd>0 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal sum</dt><dd>4626.90 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal lower sum</dt><dd>2113.91 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 withdrawal upper sum</dt><dd>34359.21 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption available sum</dt><dd>79.73 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption lower available sum</dt><dd>62.40 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 consumption upper available sum</dt><dd>96.06 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">USGS2008-2020 thermoelectric water-use reanalysis,published annual output filtered to2020:modeled annual-mean million gallons/day,not observed current2026 water use.958plant-year rows cover48conterminous states,not a complete facility census or data center inventory. Withdrawals include fresh/saline rows;consumption at coastal saline plants was not modeled.54Once-through saline source zero-consumption placeholders are excluded from consumption sums,not measured zero. State best/lower/upper figures are calculated sums of source plant model estimates and thermodynamic plausibility limits,not statewide statistical confidence intervals. Do not compare directly with2015county compilation as a measured trend;methods differ. HUC12 IDs and county labels do not certify parcels;README says public model-input coordinates use interpolated HUC12 centroids,not precise plant locations. No source coordinates adopted,site joins,permit/sustainable availability/datacenter allocation or causal inference. Locator: Calculated from2020 MI rows; source estimate/plausibility fields retained,not a statistical state interval.</p></dd><dt>Thermo2020 cooling basis</dt><dd>Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation.<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Annual YEAR2020 CSV coolingType and metadata coolingType domain definitions.</p></dd><dt>Thermo2020 cooling tower rows</dt><dd>17 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of MI YEAR2020 rows with exact coolingType=Recirculating Tower.</p></dd><dt>Thermo2020 cooling tower withdrawal</dt><dd>37.56 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Recirculating Tower.</p></dd><dt>Thermo2020 cooling once fresh rows</dt><dd>11 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of MI YEAR2020 rows with exact coolingType=Once-through fresh.</p></dd><dt>Thermo2020 cooling once fresh withdrawal</dt><dd>4426.86 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Once-through fresh.</p></dd><dt>Thermo2020 cooling complex rows</dt><dd>3 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of MI YEAR2020 rows with exact coolingType=Complex.</p></dd><dt>Thermo2020 cooling complex withdrawal</dt><dd>160.57 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Complex.</p></dd><dt>Thermo2020 cooling once saline rows</dt><dd>0 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of MI YEAR2020 rows with exact coolingType=Once-through saline.</p></dd><dt>Thermo2020 cooling once saline withdrawal</dt><dd>0.00 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Once-through saline.</p></dd><dt>Thermo2020 cooling pond rows</dt><dd>1 plant-year rows<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated count of MI YEAR2020 rows with exact coolingType=Recirculating pond.</p></dd><dt>Thermo2020 cooling pond withdrawal</dt><dd>1.92 million gallons per day<span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__b7%2Fce%2Fee%2Fb7ceee404ebbc37e014be1ac9098088824e00443\">U.S. Geological Survey</a>. Source: October 31, 2023. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/file/get/63adc826d34e92aad3ca5af4?f=__disk__da%2Fd9%2F78%2Fdad9784363a86225e69035d9b8c7ef7a8d99da02\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <span class=\"layer-source\"><a href=\"https://www.sciencebase.gov/catalog/item/63adc826d34e92aad3ca5af4?format=json\">U.S. Geological Survey</a>. Source: Publication date not stated. Checked: October 27, 2026.</span> <p class=\"layer-scope\">Historical2020 USGS model-assigned cooling-system categories within the958 reviewed plant-year rows. Counts are model rows,not separate cooling systems or complete state facility counts. Complex means more than one cooling system type;do not distribute Complex rows among other categories. Once-through fresh and saline are literal source categories;do not classify all other categories as freshwater. Withdrawal sums are modeled annual-mean million gallons/day,not consumption,discharge,permits or available supply. A category with no selected rows has a calculated count and sum of zero within this dataset,not evidence of no statewide physical use. All five mutually exclusive model categories partition these rows;saline consumption remains unmodeled and is not inferred from withdrawals. No source coordinates,Native joins,facility or data center allocation. Locator: Calculated sum of wd_mgd for MI YEAR2020 exact coolingType=Recirculating pond.</p></dd></dl></article>"}]}